SpO₂‑ og pulsratetesting
Simulerer SpO₂‑verdier fra 35–100 % og pulsrate fra 20–250 bpm.
1 / 2
© Contec Medical Systems Co., Ltd.
Contec Medical Systems Co., Ltd.
The MS100 is a compact and lightweight SpO₂ simulator designed for accurate testing of pulse oximeters. Using advanced signal simulation, it provides a reliable reference for verifying SpO₂ and pulse‑rate performance across a wide range of clinical conditions. The device includes the most commonly used R‑curves in the industry, such as Masimo Nellcor and BCI, ensuring broad compatibility with different manufacturers’ technologies. The simulator can reproduce both SpO₂ values and pulse rates, and supports testing under 50/60 Hz electrical interference as well as light‑induced disturbances. The perfusion index (PI) can be adjusted across a wide range, allowing evaluation of how a pulse oximeter responds to low perfusion, motion artefacts and challenging measurement environments. MS100 includes 24 preset patient profiles, covering conditions such as weak pulse, bradycardia, hypoxia, infant, tachycardia, elderly and obesity. The device is supplied with a simulator finger, adapter and user manual, and features a robust design with low weight and compact dimensions. Equipped with a rechargeable lithium battery, the MS100 is built for efficient and reliable testing in both clinical and technical settings.
We can help with availability, documentation and correct use.
The MS100 is a compact and lightweight SpO₂ simulator designed for accurate testing of pulse oximeters. Using advanced signal simulation, it provides a reliable reference for verifying SpO₂ and pulse‑rate performance across a wide range of clinical conditions. The device includes the most commonly used R‑curves in the industry, such as Masimo Nellcor and BCI, ensuring broad compatibility with different manufacturers’ technologies. The simulator can reproduce both SpO₂ values and pulse rates, and supports testing under 50/60 Hz electrical interference as well as light‑induced disturbances. The perfusion index (PI) can be adjusted across a wide range, allowing evaluation of how a pulse oximeter responds to low perfusion, motion artefacts and challenging measurement environments. MS100 includes 24 preset patient profiles, covering conditions such as weak pulse, bradycardia, hypoxia, infant, tachycardia, elderly and obesity. The device is supplied with a simulator finger, adapter and user manual, and features a robust design with low weight and compact dimensions. Equipped with a rechargeable lithium battery, the MS100 is built for efficient and reliable testing in both clinical and technical settings.
Simulerer SpO₂‑verdier fra 35–100 % og pulsrate fra 20–250 bpm.
Simulerer målinger under 50/60 Hz elektrisk interferens og lysforstyrrelser.
PI‑område fra 0.000 % til 20.000 %, med finoppløsning ned til 0.025 %.
Tester responstid for SpO₂, pulsrate og hjertestans‑simulering.
Innebygde kurver fra Masimo, Nellcor, BCI m.fl., totalt 10 kurver (kan tilpasses).
24 forhåndsdefinerte tilstander: svak puls, bradykardi, hypoksi, spedbarn, takykardi, eldre, overvekt m.m.
Simulatorfinger (MS100‑SP), 5 V adapter og brukermanual.
189×125×56 mm (inkludert brakett). Ca. 600 g (inkludert litiumbatteri).
3.7 V oppladbart litiumbatteri.