SpO₂ and pulse‑rate testing
Simulates SpO₂ values from 35–100 % and pulse rates from 20–250 bpm.
1 / 3
© Contec Medical Systems Co., Ltd.
Contec Medical Systems Co., Ltd.
The MS100 is a compact and lightweight SpO₂ simulator designed for accurate testing of pulse oximeters. Using advanced signal simulation, it provides a reliable reference for verifying SpO₂ and pulse‑rate performance across a wide range of clinical conditions. The device includes the most commonly used R‑curves in the industry, such as Masimo Nellcor and BCI, ensuring broad compatibility with different manufacturers’ technologies. The simulator can reproduce both SpO₂ values and pulse rates, and supports testing under 50/60 Hz electrical interference as well as light‑induced disturbances. The perfusion index (PI) can be adjusted across a wide range, allowing evaluation of how a pulse oximeter responds to low perfusion, motion artefacts and challenging measurement environments. MS100 includes 24 preset patient profiles, covering conditions such as weak pulse, bradycardia, hypoxia, infant, tachycardia, elderly and obesity. The device is supplied with a simulator finger, adapter and user manual, and features a robust design with low weight and compact dimensions. Equipped with a rechargeable lithium battery, the MS100 is built for efficient and reliable testing in both clinical and technical settings.
We can help with availability, documentation and correct use.
The MS100 is a compact and lightweight SpO₂ simulator designed for accurate testing of pulse oximeters. Using advanced signal simulation, it provides a reliable reference for verifying SpO₂ and pulse‑rate performance across a wide range of clinical conditions. The device includes the most commonly used R‑curves in the industry, such as Masimo Nellcor and BCI, ensuring broad compatibility with different manufacturers’ technologies. The simulator can reproduce both SpO₂ values and pulse rates, and supports testing under 50/60 Hz electrical interference as well as light‑induced disturbances. The perfusion index (PI) can be adjusted across a wide range, allowing evaluation of how a pulse oximeter responds to low perfusion, motion artefacts and challenging measurement environments. MS100 includes 24 preset patient profiles, covering conditions such as weak pulse, bradycardia, hypoxia, infant, tachycardia, elderly and obesity. The device is supplied with a simulator finger, adapter and user manual, and features a robust design with low weight and compact dimensions. Equipped with a rechargeable lithium battery, the MS100 is built for efficient and reliable testing in both clinical and technical settings.
Simulates SpO₂ values from 35–100 % and pulse rates from 20–250 bpm.
Simulates measurements at 50/60 Hz electrical interference and light‑induced disturbance.
PI range from 0.000 % to 20.000 %, featuring resolution down to 0.025 %.
Evaluates the response time for SpO₂, pulse rate, and cardiac‑arrest simulation.
Integrated curves from Masimo, Nellcor, BCI and others, total 10 curves (customizable).
24 predefined conditions including weak pulse, bradycardia, hypoxia, infant, tachycardia, elderly, high BMI, and others.
Simulator finger (MS100‑SP), 5 V adapter, and user manual.
189×125×56 mm (including bracket); approx. 600 g (including lithium battery).
3.7 V rechargeable lithium battery.